Service time: Monday to Friday 9:00-18:00
AXL F AO4 XC 1H - AXL F AO4 XC 1H 2702153 PHOENIX CONTACT I/O module
In Stock Hot Product

AXL F AO4 XC 1H

AXL F AO4 XC 1H 2702153 PHOENIX CONTACT I/O module

$0.00 USD
3182 in stock
Key Specifications
: Transient protection; Suppressor diode
Type: block modular
Depth: 54 mm
Width: 35 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
Transient protection; Suppressor diode
Type block modular
Depth 54 mm
Width 35 mm
Height 126.1 mm
Certificate UL 20 ATEX 2441X
Output name Analog outputs
Current draw max. 150 mA
Data formats IB IL, S7-compatible
Product type I/O component
Mounting type DIN rail mounting
Identification  II 3 G Ex ec IIC T4 Gc
Product family Axioline F
Supply voltage 5 V DC (via bus base module)
Connection name Axioline F connector
Article revision 07
Pollution degree 2 (IEC 60664-1, EN 60664-1)
Protection class III (IEC 61140, EN 61140, VDE 0140-1)
Stripping length 8 mm
Connection method Bus base module
Mounting position any (no temperature derating)
Number of outputs 4
Scope of delivery including bus base module and Axioline F connectors
Input address area 8 Byte
Note on dimensions The depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715).
Protective circuit Short-circuit and overload protection; electronic
Special properties Extreme conditions version
Transmission speed 100 Mbps
Dimensional drawing
Note on application Only for industrial use
Output address area 8 Byte
Process data update 140 µs
Degree of protection IP20
Number of interfaces 2
Overvoltage category II (IEC 60664-1, EN 60664-1)
Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Connection technology 2-conductor
Current output signal 0 mA ... 20 mA
Voltage output signal 0 V ... 5 V
References to standards EN IEC 60079-0, EN IEC 60079-7
Required parameter data 14 Byte
Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
D/A converter resolution 16 bit
Conductor cross section AWG 24 ... 16
Required configuration data 7 Byte
Conductor cross section rigid 0.2 mm² ... 1.5 mm²
Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section, rigid 0.2 mm² ... 1.5 mm²
Ambient temperature (operation) -25 °C ... 60 °C (Standard, applications with UL approval, use in zone 2 potentially explosive area)
Load/output load current output ≤ 500 Ω
Load/output load voltage output ≥ 1 kΩ
Representation of output values 16 bits (15 bits + sign)
Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Conductor cross section flexible 0.2 mm² ... 1.5 mm²
Permissible humidity (operation) 5 % ... 95 % (non-condensing)
Conductor cross section, flexible 0.2 mm² ... 1.5 mm²
Ambient temperature (storage/transport) -40 °C ... 85 °C
Note regarding the connection technology shielded, twisted pair
Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
Test voltage: 24 V supply (I/O)/analog outputs 500 V AC, 50 Hz, 1 min.
Test voltage: Analog outputs/functional ground 500 V AC, 50 Hz, 1 min.
Maximum power dissipation for nominal condition 3.4 W
Test voltage: 24 V supply (I/O) / functional ground 500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply of the local bus (UBus)/analog outputs 500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply of the local bus (UBus) / functional ground 500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply of the local bus (UBus) / 24 V supply (I/Os) 500 V AC, 50 Hz, 1 min.

Product Description

AxiolineF, Analog Output Module, Analog Outputs: 4, 0 V ... 5 V, -5 V ... 5 V, 0 V ... 10 V, -10 V ... 10 V, 0 mA... 20 mA, 4 mA... 20 mA, connection technology: 2 conductors, transmission rate on loc
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top