Technical Specifications

Parameter Value
EAN 4042949437697
EMC Declaration of Conformity
UPC 804766981197
ETIM 7
IDEA 4
depth 120 mm
other Dangerous Good
width 210 mm
UNSPSC 15
eClass 12
height 328 mm
Group Code P360
Net Weight 12.76 kg
depth [in] 4.72 in
width [in] 8.27 in
height [in] 12.91 in
● maximum 600 A
● minimum 240 A
Confirmation
Metal Factor LPB-----
● at 240 V 200 kA
● at 415 V 110 kA
● at 480 V 100 kA
● at 600 V 50 kA
● at 690 V 35 kA
Date8/25/2023 Subject to change without notice© Copyright Siemens 2023
Product Group 5383
Product class C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Quantity Unit 1 Piece
● at 40 °C 600 A
● at 45 °C 600 A
● at 50 °C 600 A
● at 55 °C 600 A
● at 60 °C 600 A
● at 65 °C 555 A
● at 70 °C 510 A
Commodity Code 85362090
Product family 3VA Molded Case Circuit Breakers up to 2000 A, UL / IEC
last modified: 8/14/2023
Net Weight (kg) 12,760 Kg
number of poles 3
product function
Country of origin Mexico
product component
● initial value 120 A
LKZ_FDB/ CatalogID LV10
Packaging Quantity 1
product brand name SENTRON
● trip indicator No
Packaging Dimension 250,00 x 360,00 x 180,00
Product Description Circuit breaker 3VA6 UL Frame 800 breaking capacity class C 100kA @ 480 V 3-pole, Line protection ETU860, LSIG, In=600A overload protection, 100% rated Ir=240A ...600A Short-circuit protection Isd=0.6..12x In, Ii=1.5..12x In N conductor protection optionally with external CT up to 160% Ground-fault protection Ig=0.2... 1 x In, tg=0.05-0.8s
ambient temperature
operational current
product designation Molded-case circuit breaker
● voltage trigger No
● full-scale value 600 A
design of the product System protection
Product Lifecycle (PLM) PM300:Active Product
power loss [W] / maximum 151 W
● undervoltage release No
current breaking capacity
Export Control Regulations AL : N / ECCN : EAR99
● communication function Yes
Standard lead time ex-works 25 Day/Days
Surcharge for Raw Materials None
Package size unit of measure MM
● during storage / maximum 80 °C
● during storage / minimum -40 °C
● during operation / maximum 70 °C
● during operation / minimum -25 °C
● other measurement function Yes
ground-fault monitoring version Summation current formation L-conductor
insulation voltage / rated value 800 V
design of the overcurrent release ETU860
protection class IP / on the front IP40
design of the N-conductor protection adjustable OFF; 20% to 160%
Article Number (Market Facing Number) 3VA6560-7KQ32-2AA0
WEEE (2012/19/EU) Take-Back Obligation Yes
operating voltage / at AC / rated value 690 V
product function / grounding protection Yes
reference code / according to IEC 81346-2 Q
product designation / according to UL file CMAE
product extension / optional / motor drive No
short-circuit current making capacity (Icm)
number of CO contacts / for auxiliary contacts 0
protection function of the overcurrent release LSIG
switching capacity class of the circuit breaker C
adjustable setting current (InN) / for N-tripping
electrical endurance (operating cycles) / at 480 V 5 100
electrical endurance (operating cycles) / at 600 V 3 500
marking / according to UL 489 / 100%-rated breaker Yes
Region Specific PriceGroup / Headquarter Price Group 12P / 1CB
mechanical service life (operating cycles) / typical 10 000
maximum short-circuit current breaking capacity (Icu)
operating short-circuit current breaking capacity (Ics)
type of electrical connection / for main current circuit nut keeper kit on both ends
adjustable delay time / of S-trip / with I2t characteristic 0.5 s
electrical endurance (operating cycles) / at AC-1 / at 690 V 3 500
adjustable response value setting current (Ii) / for I-tripping
arrangement of electrical connectors / for main current circuit Front connection
electrical endurance (operating cycles) / at AC-1 / at 380/415 V 5 100
total break time / for G-tripping / with standard characteristic
Compliance with the substance restrictions according to RoHS directive Since: 09.07.2019
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Silicic acid, lead s... CAS-No. 11120-22-2 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Silicic acid, lead saltBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Perfluorobutane sulfonic ... > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Perfluorobutane sulfonic acid (PFBS) and its saltsBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
adjustable current response value current / of instantaneous short-circuit trip unit
adjustable response value delay time (tg) / for G-tripping / with I0t characteristic
adjustable response value delay time (tg) / for G-tripping / with I2t characteristic
adjustable response value delay time (tr) / for L-tripping / with I2t characteristic
adjustable response value delay time (tsd) / for S-tripping / with I0t characteristic
adjustable response value delay time (tsd) / for S-tripping / with I2t characteristic
adjustable response value setting current (Isd) / of S-trip / with I0t characteristic
adjustable response value setting current (Isd) / of S-trip / with I2t characteristic
certificate of suitability / as approval for NAVAL (no combat vessels) / supplement SB Yes
adjustable response value setting current (Ir) / of the L-trip / with I2t characteristic
adjustable current response value current / for G-tripping / with standard characteristic
adjustable response value setting current (Ig) / for G-tripping / with I2t characteristic
type of connectable conductor cross-sections / for flat-bar terminal connection / maximum 50 x 28 mm
type of connectable conductor cross-sections / for flat-bar terminal connection / minimum 20 x 4 mm
power loss [W] / for rated value of the current / at AC / in hot operating state / per pole 50.33 W
product feature / for neutral conductors / upgradable/retrofittable / short-circuit and overload proof Yes
design of the load switch / according to UL 489 / Heating, Air Conditioning, and Refrigeration circuit breaker (HACR Type) Yes
General Product ApprovalConfirmationMiscellaneousEMCDeclaration of ConformityTest CertificatesMarine / ShippingType Test Certificates/Test ReportotherDangerous GoodConfirmationMiscellaneousMiscellaneousTransport Information General Product Approval

Product Description

circuit breaker 3VA6 UL frame 800 breaking capacity class C 100kA @ 480 V 3-pole, line protection ETU860, LSIG, In=600A overload protection Ir=240A ... 600A short circuit protection. Manufactured to o
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Confirmation

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top