Service time: Monday to Friday 9:00-18:00
3VA2440-7JP32-0AA0 - 3VA2440-7JP32-0AA0 SIEMENS circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu 110kA @ 415V 3-p..
In Stock Hot Product

3VA2440-7JP32-0AA0

3VA2440-7JP32-0AA0 SIEMENS circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu 110kA @ 415V 3-p..

$0.00 USD
3344 in stock
Key Specifications
: Confirmation
EAN: 4042948807552
UPC: 804766432729
ETIM: 5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
Confirmation
EAN 4042948807552
UPC 804766432729
ETIM 5
IDEA 4
Width 138 mm
depth 110 mm
Height 248 mm
UNSPSC 15
eClass 6
Group Code P360
Net Weight 4.3 kg
depth [in] 4.33 in
width [in] 5.43 in
height [in] 9.76 in
Date5/9/2022
Metal Factor LOA-----
● at 240 V 150 kA
● at 415 V 110 kA
● at 440 V 110 kA
● at 500 V 85 kA
● at 690 V 6 kA
Miscellaneous
Product Group 5374
Product class C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Quantity Unit 1 Piece
● at 40 °C 400 A
● at 45 °C 400 A
● at 50 °C 400 A
● at 55 °C 400 A
● at 60 °C 400 A
● at 65 °C 400 A
● at 70 °C 400 A
Commodity Code 85362090
Product family 3VA Molded Case Circuit Breakers up to 1600 A, IEC
last modified: 10/2/2021
Net Weight (kg) 4,300 Kg
Product version Line protection
number of poles 3
product function
Country of origin Czech Republic
Marine / Shipping other
product component
LKZ_FDB/ CatalogID LV10.1
Packaging Quantity 1
product brand name SENTRON
● limited to 1 s 5 kA
● trip indicator No
Packaging Dimension 165,00 x 265,00 x 170,00
Product Description circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..15x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit
ambient temperature
operational current
product designation Molded case circuit breaker
● voltage trigger No
Product Lifecycle (PLM) PM300:Active Product
General Product Approval EMC
Rated voltage (EF003977) ['690', '690']
power loss [W] / maximum 63.5 W
● undervoltage release No
Declaration of Conformity Test Certificates
Export Control Regulations AL : N / ECCN : EAR99
Number of poles (EF001391) 3
● communication function Yes
Standard lead time ex-works 20 Day/Days
Surcharge for Raw Materials None
rated insulation voltage Ui 800 V
Package size unit of measure MM
● during storage / maximum 80 °C
● during storage / minimum -40 °C
Courant permanent assigné Iu 400 A
Device construction (EF008240) Built-in device fixed built-in technique
● during operation / maximum 70 °C
● during operation / minimum -25 °C
● other measurement function No
Motor drive optional (EF007386) true
ground-fault monitoring version Without
Motor drive integrated (EF006697) false
design of the overcurrent release ETU550
Type of control element (EF006976) Rocker lever
protection class IP / on the front IP40
short-time withstand current (Icw)
Degree of protection (IP) (EF005474) IP40
design of the N-conductor protection adjustable OFF; 20% to 160%
Article Number (Market Facing Number) 3VA2440-7JP32-0AA0
Rated permanent current Iu (EF001389) 400.0
With under voltage release (EF007518) -
WEEE (2012/19/EU) Take-Back Obligation Yes
With switched-off indicator (EF007006) -
reference code / according to IEC 81346-2 Q
product extension / optional / motor drive Yes
● at AC / limited to 0.5 s / rated value 5 kA
Adjustable response value current / li max. 6 000 A
Adjustable response value current / li min. 600 A
Overload release current setting (EF002336) ['160', '400']
short-circuit current making capacity (Icm)
Integrated earth fault protection (EF007296) false
Neutral conductors / upgradeable/retrofittable Yes
number of CO contacts / for auxiliary contacts 0
protection function of the overcurrent release LSI
Complete device with protection unit (EF008906) true
switching capacity class of the circuit breaker C
Max. rated operational current of the frame size 630 A
DIN rail (top hat rail) mounting optional (EF008904) true
Region Specific PriceGroup / Headquarter Price Group 12P / 1CB
mechanical service life (switching cycles) / typical 20 000
breaking capacity maximum short-circuit current (Icu)
breaking capacity operating short-circuit current (Ics)
Suitable for DIN rail (top hat rail) mounting (EF007250) true
Type of electrical connection of main circuit (EF006819) Screw connection
type of electrical connection / for main current circuit on both sides nut keeper kit
Ground fault protection / tripping switchable / I2t=ON/OFF No
Position of connection for main current circuit (EF006671) Front side
Adjustment range undelayed short-circuit release (EF007131) ['600', '6000']
Number of auxiliary contacts as change-over contact (EF003531) 0
arrangement of electrical connectors / for main current circuit Front terminal
Number of auxiliary contacts as normally open contact (EF001376) 0
Number of auxiliary contacts as normally closed contact (EF001377) 0
Adjustment range short-term delayed short-circuit release (EF007129) ['240', '4000']
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz (EF007048) 110.0
Electrical endurance (switching cycles) / at AC-1 / at 690 V 50/60 Hz 3 500
Compliance with the substance restrictions according to RoHS directive Since: 01.04.2014
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Silicic acid, lead s... CAS-No. 11120-22-2 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Silicic acid, lead saltBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
Electrical endurance (switching cycles) / at AC-1 / at 380/415 V 50/60 Hz 5 000
Type of connectable conductor cross-section, connection screw, width x thickness , max. 35 x 10 mm
Type of connectable conductor cross-section, connection screw, width x thickness , min. 20 x 1 mm
Active power loss / for rated value of the current / at AC / in hot operating state / per pole 21.17 W
General Product ApprovalEMCConfirmationMiscellaneousDeclaration of ConformityTest CertificatesMarine / ShippingUK Declaration of ConformityType Test Certificates/Test ReportSpecial Test CertificateMiscellaneousMarine / ShippingotherCCS / China Classification SocietyMiscellaneousotherMiscellaneous General Product Approval

Product Description

AUTOMATIC SWITCH 3VA2 IEC SIZE 630 CUTTING POWER CLASS C ICU=110KA @ 415 V 3 POLES, PROTEC. ETU550, LSI, IN=400A OVERLOAD PROTECTION IR=160A ... 400A SHORT CIRCUIT PROTECTION ISD=0,6..10X IN, II=1,5..
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top