Service time: Monday to Friday 9:00-18:00
3VA2125-6HM32-0AA0 - 3VA2125-6HM32-0AA0 SIEMENS circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu 85kA @ 415V 3-po..
In Stock Hot Product

3VA2125-6HM32-0AA0

3VA2125-6HM32-0AA0 SIEMENS circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu 85kA @ 415V 3-po..

$0.00 USD
3158 in stock
Key Specifications
: Confirmation
EAN: 4042948801871
EMC: Declaration of Conformity
UPC: 804766438479
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
Confirmation
EAN 4042948801871
EMC Declaration of Conformity
UPC 804766438479
ETIM 5
IDEA 4
Width 105 mm
depth 86 mm
Height 181 mm
UNSPSC 15
eClass 6
Group Code P360
Net Weight 2.5 kg
depth [in] 3.39 in
width [in] 4.13 in
height [in] 7.13 in
Metal Factor LOA-----
● at 240 V 110 kA
● at 415 V 85 kA
● at 440 V 85 kA
● at 500 V 55 kA
● at 690 V 2.5 kA
Date5/17/2022
Miscellaneous
Product Group 5374
Product class C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Quantity Unit 1 Piece
● at 40 °C 25 A
● at 45 °C 25 A
● at 50 °C 25 A
● at 55 °C 25 A
● at 60 °C 25 A
● at 65 °C 25 A
● at 70 °C 25 A
Commodity Code 85362010
Product family 3VA Molded Case Circuit Breakers up to 1600 A, IEC
last modified: 10/8/2021
Net Weight (kg) 2,500 Kg
Product version Line protection
number of poles 3
product function
Country of origin Czech Republic
Marine / Shipping other
product component
LKZ_FDB/ CatalogID LV10.1
Packaging Quantity 1
product brand name SENTRON
● trip indicator No
Packaging Dimension 134,00 x 200,00 x 145,00
Product Description circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU330, LIG, In=25A overload protection Ir=10A...25A short-circuit protection Ii=1.5...12 x In ground-fault protection Ig=0.6... 1 x In, tg=0.1/0.3s nut keeper kit
ambient temperature
operational current
product designation Molded case circuit breaker
● voltage trigger No
Product Lifecycle (PLM) PM300:Active Product
Rated voltage (EF003977) ['690', '690']
power loss [W] / maximum 0.6 W
● undervoltage release No
Export Control Regulations AL : N / ECCN : EAR99
Number of poles (EF001391) 3
● communication function No
Standard lead time ex-works 15 Day/Days
Surcharge for Raw Materials None
rated insulation voltage Ui 800 V
Package size unit of measure MM
● during storage / maximum 80 °C
● during storage / minimum -40 °C
Courant permanent assigné Iu 25 A
Device construction (EF008240) Built-in device fixed built-in technique
● during operation / maximum 70 °C
● during operation / minimum -25 °C
● other measurement function No
Motor drive optional (EF007386) true
ground-fault monitoring version Summation current formation L-conductor
Motor drive integrated (EF006697) false
design of the overcurrent release ETU330
Type of control element (EF006976) Rocker lever
protection class IP / on the front IP40
Degree of protection (IP) (EF005474) IP40
Article Number (Market Facing Number) 3VA2125-6HM32-0AA0
Rated permanent current Iu (EF001389) 25.0
With under voltage release (EF007518) -
WEEE (2012/19/EU) Take-Back Obligation Yes
With switched-off indicator (EF007006) -
reference code / according to IEC 81346-2 Q
product extension / optional / motor drive Yes
Adjustable response value current / lg max. 25 A
Adjustable response value current / lg min. 15 A
Adjustable response value current / li max. 300 A
Adjustable response value current / li min. 38 A
Overload release current setting (EF002336) ['10', '25']
short-circuit current making capacity (Icm)
Integrated earth fault protection (EF007296) true
Neutral conductors / upgradeable/retrofittable No
number of CO contacts / for auxiliary contacts 0
protection function of the overcurrent release LIG
Complete device with protection unit (EF008906) true
switching capacity class of the circuit breaker H
Max. rated operational current of the frame size 160 A
DIN rail (top hat rail) mounting optional (EF008904) true
Region Specific PriceGroup / Headquarter Price Group 12P / 1CB
mechanical service life (switching cycles) / typical 25 000
breaking capacity maximum short-circuit current (Icu)
breaking capacity operating short-circuit current (Ics)
Suitable for DIN rail (top hat rail) mounting (EF007250) true
Type of electrical connection of main circuit (EF006819) Screw connection
type of electrical connection / for main current circuit on both sides nut keeper kit
Ground fault protection / tripping switchable / I2t=ON/OFF Yes
Position of connection for main current circuit (EF006671) Front side
Adjustment range undelayed short-circuit release (EF007131) ['38', '300']
Number of auxiliary contacts as change-over contact (EF003531) 0
arrangement of electrical connectors / for main current circuit Front terminal
Number of auxiliary contacts as normally open contact (EF001376) 0
Number of auxiliary contacts as normally closed contact (EF001377) 0
Adjustment range short-term delayed short-circuit release (EF007129) ['-', '-']
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz (EF007048) 85.0
Electrical endurance (switching cycles) / at AC-1 / at 690 V 50/60 Hz 9 800
Compliance with the substance restrictions according to RoHS directive Since: 01.06.2012
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Silicic acid, lead s... CAS-No. 11120-22-2 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Silicic acid, lead saltBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
Electrical endurance (switching cycles) / at AC-1 / at 380/415 V 50/60 Hz 14 000
design of the surface / of the connections / on the top of the switch (N, 1, 3, 5) tin
Type of connectable conductor cross-section, connection screw, width x thickness , max. 25 x 8 mm
Type of connectable conductor cross-section, connection screw, width x thickness , min. 13 x 1 mm
Active power loss / for rated value of the current / at AC / in hot operating state / per pole 0.2 W
General Product ApprovalConfirmationMiscellaneousEMCDeclaration of ConformityTest CertificatesUK Declaration of ConformitySpecial Test CertificateType Test Certificates/Test ReportMiscellaneousMarine / ShippingotherCCS / China Classification SocietyMiscellaneousotherMiscellaneous General Product Approval

Product Description

AUTOM SWITCH. 3VA2 IEC SIZE 160 CUTTING POWER CLASS H ICU=85KA @ 415 V 3 POLOS, PROTEC. ETU330, LIG, IN=25A OVERLOAD PROTECTION IR=10A ... 25A SHORT CIRCUIT PROTECTION II=1,5...12 X IN GROUND DEFECT P
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top