Technical Specifications

Parameter Value
EAN 4011209765580
UPC Not available
ETIM 5
depth 161.6 mm
width 209.4 mm
UNSPSC 14
eClass 6
height 306 mm
● open IP20
Group Code P360
net weight 4.35 kg
fuse system LV HRC fuse
● maximum 12 N·m
● minimum 10 N·m
Date5/3/2022
Metal Factor LCP-----
power factor
Product Group 5863
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit 1 Piece
Commodity Code 85362090
Product family Basic Devices
power loss [W]
type of device For assembly and installation on mounting plate
● at AC-22 B 0.65
● at AC-23 B 0.35
Net Weight (kg) 4,044 Kg
number of poles 3
● main switch No
● motor drive No
● rated value 690 V
fastening method mounting plate
product function
● on the front IP40
Country of origin Czech Republic
mounting position horizontal/vertical
operating voltage
size of fuse link NH1, NH2
● rail mounting No
● safety switch Yes
LKZ_FDB/ CatalogID LV10.1
Packaging Quantity 1
insulation voltage
product brand name SENTRON
● floor mounting Yes
Packaging Dimension 226,00 x 385,00 x 287,00
Product Description SENTRON, Fuse switch disconnector 3NP1, 3-pole, NH2, 400 A, for assembly and installation on mounting plate, flat terminal, Fuse monitoring: electronic EFM20, Cover level 70 mm
degree of pollution 2
operational current
product designation 3NP1 fuse switch disconnector
protection class IP
suitability for use
● fuse monitoring Yes
● voltage trigger No
design of the product cover level 70 mm
Cable entry (EF000537) -
● locking capability Yes
● stranded / maximum 240 mm²
● stranded / minimum 25 mm²
Product Lifecycle (PLM) PM300:Active Product
● at AC / rated value 400 A
● switch disconnector Yes
● EMERGENCY OFF switch No
● with capacitive load -0.25
Declaration of Conformity Test Certificates
power factor / at AC-21 B 0.95
● 4-hole front mounting No
Export Control Regulations AL : N / ECCN : EAR99
Number of poles (EF001391) 3
product feature / sealable Yes
size of disconnecting link 2 and 1
Standard lead time ex-works 30 Day/Days
Surcharge for Raw Materials None
product feature / interlock Yes
● at 35 °C / rated value 400 A
● at 40 °C / rated value 400 A
● at 45 °C / rated value 392 A
● at 50 °C / rated value 372 A
● at 55 °C / rated value 356 A
Package size unit of measure MM
product extension / optional
Suitable for fuses (EF006692) NH1, NH2
type of connection technology Flat terminal
● maintenance/repair switch Yes
Motor drive optional (EF007386) false
design of the actuating element Cover handle
design of the safety monitoring electronic EFM 20
● solid or stranded / maximum 240 mm²
● solid or stranded / minimum 25 mm²
With error protection (EF007384) true
Motor drive integrated (EF006697) false
Version as main switch (EF006981) false
● at AC / rated value / maximum 690 V
● at AC / rated value / minimum 230 V
Type of control element (EF006976) Cover grip
Equipped with connectors (EF011696) false
Position control element (EF009410) Front side
Version as safety switch (EF006985) true
ambient temperature / during storage
product extension / auxiliary switch Yes
● of the fuse / per fuse / maximum 34 W
Article Number (Market Facing Number) 3NP1153-1DA13
Rated permanent current Iu (EF001389) 400.0
● overvoltage protection monitoring Yes
Suitable for floor mounting (EF007243) true
Suitable for front mounting (EF007246) false
WEEE (2012/19/EU) Take-Back Obligation Yes
ambient temperature / during operation
design of the load switch / strip form No
surge voltage resistance / rated value 8 kV
● product component / trip indicator Yes
Suitable for busbar mounting (EF007259) false
● at AC-21 B / at 240 V / rated value 400 A
● at AC-21 B / at 400 V / rated value 400 A
● at AC-21 B / at 500 V / rated value 400 A
● at AC-21 B / at 690 V / rated value 400 A
● at AC-22 B / at 240 V / rated value 400 A
● at AC-22 B / at 400 V / rated value 400 A
● at AC-22 B / at 500 V / rated value 400 A
● at AC-22 B / at 690 V / rated value 400 A
● at AC-23 B / at 240 V / rated value 400 A
● at AC-23 B / at 400 V / rated value 400 A
● at AC-23 B / at 500 V / rated value 315 A
● at AC-23 B / at 690 V / rated value 125 A
● front mounting with central attachment No
type of the driving mechanism / motor drive No
● product component / undervoltage release No
Max. rated operation voltage Ue AC (EF007355) 690
tightening torque / with screw-type terminals
number of CO contacts / for auxiliary contacts 0
number of NC contacts / for auxiliary contacts 0
number of NO contacts / for auxiliary contacts 0
● product function / phase failure monitoring Yes
Degree of protection (IP), front side (EF003118) IP40
Rated operation power at AC-23, 400 V (EF007027) -
Rated short-time withstand current lcw (EF007050) -
Version as emergency stop installation (EF006959) false
● with capacitive load / at 400 V / rated value 72 A
● with capacitive load / at 500 V / rated value 55 A
Region Specific PriceGroup / Headquarter Price Group 14M / 1DL
mechanical service life (switching cycles) / typical 1 000
● with degree of pollution 2 / at AC / rated value 1 000 V
● with degree of pollution 3 / at AC / rated value 690 V
Conditioned rated short-circuit current Iq (EF001444) 80.0
● with closed switch / with cover or cable lug cover IP40
connectable conductor cross-section / for main contacts
Type of electrical connection of main circuit (EF006819) Rail connection
type of electrical connection / for main current circuit busbar connection
● with closed switch / without cover or cable lug cover IP30
let-through current / with closed switch / maximum permissible 40 kA
arrangement of electrical connectors / for main current circuit other
● product component / undervoltage release with leading contact No
● with conventional rated thermal current / without fuse / per pole 14 W
Compliance with the substance restrictions according to RoHS directive Since: 23.10.2008
let-through current / with high-speed activation / maximum permissible 40 kA
● with conventional rated thermal current / without fuse / per device 42 W
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
● for rated value of the current / at AC / in hot operating state / per pole 48 W
type of connectable conductor cross-sections / of the laminated conductors / maximum 34 x 18 mm
General Product ApprovalConfirmationMiscellaneousDeclaration of ConformityTest CertificatesMarine / ShippingotherUK Declaration of ConformityType Test Certificates/Test ReportMiscellaneous General Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top