Service time: Monday to Friday 9:00-18:00
3KL5740-1GG01 - 3KL5740-1GG01 SIEMENS Switch disconnector with fuse in new design Iu 400 A, Ue 690 V, 4-pole for BS88 fuse f..
In Stock Hot Product

3KL5740-1GG01

3KL5740-1GG01 SIEMENS Switch disconnector with fuse in new design Iu 400 A, Ue 690 V, 4-pole for BS88 fuse f..

$0.00 USD
3086 in stock
Key Specifications
: Value
EAN: 4011209739345
UPC: Not available
ETIM: 4
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
Value
EAN 4011209739345
UPC Not available
ETIM 4
Depth 209 mm
Notes Sucessor:3KF4340-0MF11, different dimensions, some deviating technical values.
Width 293 mm
Height 160 mm
UNSPSC 14
eClass 6
version Complete version with rotary operating mechanism
● 400V 80 kA
● 500V 80 kA
Group Code P360
Design type For mounting and installation
Fuse system fuses according to BS 88
Price Group 12S
● maximum 55 °C
● minimum -25 °C
Metal Factor LAO-----
Mounting type Surface mounting and installation
Product Group 5853
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit 1 Piece
Commodity Code 85362090
Product family Not available
Net Weight (kg) 7,090 Kg
Operating power
number of poles 4
type of voltage AC/DC
Type of mounting fixed mounted
Country of origin Germany
Operating voltage
mounting position any
LKZ_FDB/ CatalogID LV10.1
PLM Effective Date Product phase-out since: 31.08.2018
Packaging Quantity 1
product brand name SENTRON
Packaging Dimension 209,00 x 309,00 x 252,00
Product Description Switch disconnector with fuse in new design Iu=400 A, Ue = 690 V, 4-pole for BS88 fuse form B1/B3 4th pole selectable, without Fuse with door operating mechanism 8UC7 Handle dark blue/blue-green Basic masking frame light gray
Product designation Switch disconnector
Protection class IP IP00
Design of the product With 3KL fuses
● AC-21 A / at 400 V 400 A
● AC-21 A / at 500 V 400 A
● AC-21 B / at 400 V 400 A
● AC-21 B / at 500 V 400 A
● AC-22 A / at 400 V 400 A
● AC-22 A / at 500 V 400 A
● AC-22 B / at 400 V 400 A
● AC-22 B / at 500 V 400 A
● stranded / maximum 240 mm²
Product Lifecycle (PLM) PM400:Phase Out Started
● at DC / rated value 440 V
Interlockable (EF006281) true
Declaration of Conformity Test Certificates
Export Control Regulations AL : N / ECCN : N
Number of poles (EF001391) 4
Size of disconnecting link Form B1-B3
certificate of suitability CE
Product feature / interlock Yes
Standard lead time ex-works 15 Day/Days
Surcharge for Raw Materials None
Package size unit of measure MM
Number of switches (EF005586) -
Device construction (EF008240) Built-in device fixed built-in technique
Product Dimensions (W x L x H) Not available
Motor drive optional (EF007386) false
Operating current / rated value 400 A
Continuous current / rated value 400 A
Insulation voltage / rated value 1 000 V
Type of connection, main circuit flat pad connection, M10
Colour control element (EF007167) -
Design of the operating mechanism manual operating mechanism
Motor drive integrated (EF006697) false
Version as main switch (EF006981) true
● mounting type / rail mounting No
Rated operating voltage (EF001435) -
Type of control element (EF006976) Other
Switching power at 400 V (EF009166) -
Version as safety switch (EF006985) true
Voltage release optional (EF007491) false
Ambient temperature / during storage
Article Number (Market Facing Number) 3KL5740-1GG01
Rated permanent current Iu (EF001389) 400.0
● at AC / at 50/60 Hz / rated value 690 V
Ambient temperature / during operation
Degree of protection (NEMA) (EF011959) -
Design of the load switch / Strip form No
Suitable for floor mounting (EF007243) FALSE
Surge voltage resistance / rated value 8 000 V
Version as reversing switch (EF009408) -
WEEE (2012/19/EU) Take-Back Obligation Yes
Conditional rated short-circuit current
● at AC-23 A / at 500 V / rated value 200 000 W
Number of poles / for main current circuit 4
Operating current / at AC-21 / rated value 400 A
Type of the driving mechanism / motor drive No
● reference code / acc. to DIN EN 61346-2 Q
Max. rated operation voltage Ue AC (EF007355) 690
Suitable for front mounting 4-hole (EF007247) false
Suitable for front mounting centre (EF007248) false
Suitable for intermediate mounting (EF007264) false
Number of CO contacts / for auxiliary contacts 0
Number of NC contacts / for auxiliary contacts 0
Number of NO contacts / for auxiliary contacts 0
Rated operation power at AC-3, 400 V (EF001364) -
Degree of protection (IP), front side (EF003118) IP00
Rated operation power at AC-23, 400 V (EF007027) 200.0
● in utilization category / AC-21 A / at 400 V 80 kA
● in utilization category / AC-21 A / at 500 V 80 kA
● in utilization category / AC-21 B / at 400 V 80 kA
● in utilization category / AC-21 B / at 500 V 80 kA
● in utilization category / AC-22 A / at 400 V 80 kA
● in utilization category / AC-22 A / at 500 V 80 kA
● in utilization category / AC-22 B / at 400 V 80 kA
● in utilization category / AC-22 B / at 500 V 80 kA
Rated short-time withstand current lcw (EF007050) -
Version as emergency stop installation (EF006959) false
Version as maintenance-/service switch (EF006986) true
Rated permanent current at AC-21, 400 V (EF009165) -
Rated permanent current at AC-23, 400 V (EF011777) 400
Rated current Ie / maximum / in utilization category
Conditioned rated short-circuit current Iq (EF001444) -
● at AC-23 A / at 400 V / at 50/60 Hz / rated value 200 000 W
● at AC-23 A / at 690 V / at 50/60 Hz / rated value 280 000 W
Connectable conductor cross-section / for main contacts
Suitable for distribution board installation (EF007262) false
Type of electrical connection of main circuit (EF006819) Other
● Mounting type / front mounting with 4-hole attachment No
● Mounting type / front mounting with central attachment No
Number of auxiliary contacts as change-over contact (EF003531) 0
Number of auxiliary contacts as normally open contact (EF001376) 0
Number of auxiliary contacts as normally closed contact (EF001377) 0
Compliance with the substance restrictions according to RoHS directive Since: 01.06.2007
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
Power loss [W] / for rated value of the current / at AC / in hot operating state / per pole 28.7 W
Let-through current / I2 t / maximum permissible / in utilization category / AC-22 B / at 400 V 1 000 000 A²·s
Declaration of ConformityTest CertificatesShipping ApprovalotherSpecial Test CertificateEnvironmental ConfirmationsMiscellaneous Declaration of Conformity

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top