Service time: Monday to Friday 9:00-18:00
3KD2840-2NE10-0 - 3KD2840-2NE10-0 SIEMENS Switch disconnector 80 A, Size 2, 4-pole Front operating mechanism left Basic unit w..
In Stock Hot Product

3KD2840-2NE10-0

3KD2840-2NE10-0 SIEMENS Switch disconnector 80 A, Size 2, 4-pole Front operating mechanism left Basic unit w..

$0.00 USD
4199 in stock
Key Specifications
: Value
EAN: 4001869472065
UPC: Not available
ETIM: 4
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
Value
EAN 4001869472065
UPC Not available
ETIM 4
Depth 68 mm
Width 148 mm
Height 126 mm
UNSPSC 15
eClass 6
● solid 1x (2.5 ... 16 mm²)
Group Code P360
net weight 1 434 g
Price Group 12S
● maximum 70 °C
● minimum -25 °C
Metal Factor LAO-----
● stranded 1x (10 ... 70 mm²)
Mounting type Screw fixing and standard rail mounting 35 mm
Product Group 5378
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit 1 Piece
Commodity Code 85365080
Power loss [W]
Product family Basic Devices
Type of device fixed mounting
Net Weight (kg) 1,434 Kg
Operating power
number of poles 4
● Main switch Yes
● motor drive No
● rated value 1 000 V
Country of origin China
Operating voltage
Product component
mounting position any
● safety switch Yes
Continuous current
Insulation voltage
LKZ_FDB/ CatalogID LV10.1
Packaging Quantity 1
product brand name SENTRON
● Trip indicator No
Degree of pollution 3
Packaging Dimension 148,00 x 155,00 x 85,00
Product Description Switch disconnector 80 A, Size 2, 4-pole Front operating mechanism left Basic unit without handle Box terminal
Product designation 3KD switch disconnector
Protection class IP IP20
Suitability for use
● Voltage trigger No
overvoltage category III
Design of the product Switch
● for copper busbar '1 x (3 x 14 mm²)
Product Lifecycle (PLM) PM300:Active Product
● switch disconnector Yes
General Product Approval Declaration of Conformity
Interlockable (EF006281) false
● EMERGENCY OFF switch Yes
● undervoltage release No
● at AC-23 A / at 690 V 1 500
● at DC-23 A / at 440 V 1 500
Export Control Regulations AL : N / ECCN : N
Number of poles (EF001391) 4
Size of switch disconnector 2
Standard lead time ex-works 15 Day/Days
Surcharge for Raw Materials None
product feature / interlock No
● at 40 °C / rated value 80 A
● at 45 °C / rated value 80 A
● at 50 °C / rated value 80 A
● at 55 °C / rated value 80 A
● at 60 °C / rated value 80 A
● at 65 °C / rated value 80 A
● at 70 °C / rated value 80 A
Package size unit of measure MM
Product extension / optional
● for main current circuit box terminal
Number of switches (EF005586) -
Type of electrical connection
type of the driving mechanism Front operating mechanism
● maintenance/repair switch Yes
Device construction (EF008240) Built-in device fixed built-in technique
Product Dimensions (W x L x H) Not available
Motor drive optional (EF007386) false
Operating current / rated value 80 A
Colour control element (EF007167) Other
Design of the operating mechanism Without handle
Motor drive integrated (EF006697) false
Version as main switch (EF006981) true
● mounting type / rail mounting Yes
Rated operating voltage (EF001435) -
Short-time withstand current (Icw)
Type of control element (EF006976) None
Switching power at 400 V (EF009166) 37.0
Version as safety switch (EF006985) true
Voltage release optional (EF007491) false
Ambient temperature / during storage
Product extension / Auxiliary switch Yes
Article Number (Market Facing Number) 3KD2840-2NE10-0
Rated permanent current Iu (EF001389) 80.0
● at AC / at 50/60 Hz / rated value 1 000 V
Ambient temperature / during operation
Degree of protection (NEMA) (EF011959) -
Suitable for floor mounting (EF007243) FALSE
Surge voltage resistance / rated value 8 kV
Version as reversing switch (EF009408) false
WEEE (2012/19/EU) Take-Back Obligation Yes
● protection class IP / on the front IP20
Electrical endurance (switching cycles)
Operating current / at AC / rated value 80 A
Operating current / at DC / rated value 80 A
● at 500 V / by gG fuse / rated value 100 kA
● at 690 V / by gG fuse / rated value 100 kA
● at AC-23 A / at 500 V / rated value 55 kW
let-through current / with closed switch
Short-circuit current making capacity (Icm)
Type of the driving mechanism / motor drive No
● Reference code / acc. to DIN EN 81346-2 Q
● reference code / acc. to DIN EN 61346-2 Q
Position / of the switch operating mechanism at the left end
Type of connectable conductor cross-sections
Max. rated operation voltage Ue AC (EF007355) 690
Suitable for front mounting 4-hole (EF007247) false
Suitable for front mounting centre (EF007248) false
Suitable for intermediate mounting (EF007264) true
● undervoltage release with leading contact No
Number of CO contacts / for auxiliary contacts 4
Number of NC contacts / for auxiliary contacts 0
Number of NO contacts / for auxiliary contacts 0
● finely stranded / with core end processing 1x (2.5 ... 70 mm²)
Rated operation power at AC-3, 400 V (EF001364) -
Degree of protection (IP), front side (EF003118) IP20
Operating voltage / with current paths in series
Rated operation power at AC-23, 400 V (EF007027) 45.0
Rated short-time withstand current lcw (EF007050) -
Version as emergency stop installation (EF006959) true
Version as maintenance-/service switch (EF006986) true
● at 400 V AC / limited to 0.15 s / rated value 15 kA
Rated permanent current at AC-21, 400 V (EF009165) 80
Rated permanent current at AC-23, 400 V (EF011777) -
Mechanical service life (switching cycles) / typical 15 000
● with degree of pollution 2 / at DC / rated value 440 V / 3
● with degree of pollution 3 / at DC / rated value 440 V / 3
Conditioned rated short-circuit current Iq (EF001444) -
● at AC-23 A / at 400 V / at 50/60 Hz / rated value 45 kW
● at AC-23 A / at 690 V / at 50/60 Hz / rated value 75 kW
● with conventional rated thermal current / per pole 1.1 W
Suitable for distribution board installation (EF007262) true
Number of connected CO contacts / for auxiliary contacts 0
Number of connected NC contacts / for auxiliary contacts 0
Number of connected NO contacts / for auxiliary contacts 0
Type of electrical connection of main circuit (EF006819) Frame clamp
● Operating current / at AC-20 A / at 1000 V / maximum 80 A
● with conventional rated thermal current / per device 4.4 W
● Mounting type / front mounting with 4-hole attachment No
● Mounting type / front mounting with central attachment No
● Operating current / at AC-21 A / at 400 V / rated value 80 A
● Operating current / at AC-21 A / at 500 V / rated value 80 A
● Operating current / at AC-21 A / at 690 V / rated value 80 A
● Operating current / at AC-22 A / at 400 V / rated value 80 A
● Operating current / at AC-22 A / at 500 V / rated value 80 A
● Operating current / at AC-22 A / at 690 V / rated value 80 A
● Operating current / at AC-23 A / at 400 V / rated value 80 A
● Operating current / at AC-23 A / at 500 V / rated value 80 A
● Operating current / at AC-23 A / at 690 V / rated value 80 A
● at 415 V / by molded case circuit breaker / rated value 65 kA
● I2t value / of the fuse / at 500 V / maximum permissible 223 005 A²·s
Number of auxiliary contacts as change-over contact (EF003531) 4
Continuous current / of upstream fuse / at 1000 V / rated value 250 A
● I2t value / of the gG fuse / at 690 V / maximum permissible 226 005 A²·s
Number of auxiliary contacts as normally open contact (EF001376) 0
Conditional short-circuit current / with line-side fuse protection
Number of auxiliary contacts as normally closed contact (EF001377) 0
let-through current / of the fuse / at 500 V / maximum permissible 25 700 A
● for combination switch + fuse / at 400 V / maximum permissible 27 700 A
● for combination switch + fuse / at 500 V / maximum permissible 27 700 A
Type of connectable conductor cross-sections / for copper conductor
let-through current / of the aM fuse / at 690 V / maximum permissible 32 900 A
let-through current / of the gG fuse / at 690 V / maximum permissible 29 500 A
● at 690 V / for combination switch + aM fuse / maximum permissible 17 600 A
● at 690 V / for combination switch + gG fuse / maximum permissible 23 700 A
Compliance with the substance restrictions according to RoHS directive Since: 24.11.2009
● for switch disconnector / without fuse link / rated value / minimum 12 kA
Continuous current / of upstream fuse / at 500 V and 690 V / rated value 250 A
REACH Art. 33 Duty to inform according to the current list of candidates Reach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
● I2t value / of the gG/aM SITOR fuse / at 1000 V / maximum permissible 48 000 A²·s
● Protection class IP / with closed switch / with cover or cable lug cover IP20
● at 1000 V / for combination switch +gG/aM SITOR fuse / maximum permissible 10 795 A
● for rated value of the current / at AC / in hot operating state / per pole 1.1 W
let-through current / of the gG/aM SITOR fuse / at 1000 V / maximum permissible 12 500 A
● I2t value / of the molded case circuit breaker / at 415 V / maximum permissible 560 000 A²·s
● Operating current / at AC-22 A / at 400 V / at 50/60 Hz / rated value / maximum 80 A
● Operating current / at AC-22 A / at 500 V / at 50/60 Hz / rated value / maximum 80 A
● Operating current / at AC-22 A / at 690 V / at 50/60 Hz / rated value / maximum 80 A
● Operating current / at AC-23 A / at 400 V / at 50/60 Hz / rated value / maximum 80 A
● Operating current / at AC-23 A / at 500 V / at 50/60 Hz / rated value / maximum 80 A
● Operating current / at AC-23 A / at 690 V / at 50/60 Hz / rated value / maximum 80 A
Continuous current / of upstream molded case circuit breaker / at 415 V / rated value 160 A
● for switch disconnector / at 400 V AC / without fuse link / rated value / minimum 30 kA
● for switch disconnector / at DC 440 V / without fuse link / rated value / minimum 12 kA
● for switch disconnector / at 1000 V AC / without fuse link / rated value / minimum 12 kA
● I2t value / with closed switch / for combination switch + fuse / at 400 V / maximum 135 600 A²·s
● I2t value / with closed switch / for combination switch + fuse / at 500 V / maximum 135 600 A²·s
Display version / for switch position indicator door-coupling rotary operating mechanism ON-OFF
● at 415 V / for combination switch +molded case circuit breaker / maximum permissible 16 980 A
Short-time withstand current (Icw) / at AC 1000 V/DC 440 V / limited to 1 s / rated value 4 kA
let-through current / of the molded case circuit breaker / at 415 V / maximum permissible 22 500 A
● I2t value / with closed switch / at 690 V / for combination switch + aM fuse / maximum 201 200 A²·s
● I2t value / with closed switch / at 690 V / for combination switch + gG fuse / maximum 178 300 A²·s
General Product ApprovalDeclaration of ConformityShipping ApprovalotherMiscellaneousMiscellaneous General Product Approval
● I2t value / with closed switch / at 1000 V / for combination switch +gG/aM SITOR fuse / maximum 19 815 A²·s
Overvoltage in percent / relative to the operating voltage / at AC / at 400, 500, 690 V / at 50/60 Hz 10 %
● I2t value / with closed switch / at 415 V / for combination switch +molded case circuit breaker / maximum 306 000 A²·s

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top